国产精品国产三级国产在线观看_免费 日韩 av 在线_在线看丁香五月天影院av_久草新视频一区二区三区_AV综合网亚洲男人的天堂_99久热国产精品_91精品国产高清在线看_国产激情性色视频在线观看欧美亚洲激情_亚洲五月天婷婷狠狠_农民三级影片大全在线播放视频

PY602/H /S intelligent digital pressure and temperature meter
    It integrates a number of international advanced electronic technology, single chip computer technology, electric erasure technology and anti-interference technology;
    It has the advantages of high measurement and control precision and strong anti-interference performance;
    The pressure and temperature are collected and controlled at the same time;
    Double four high brightness green and red LED, display resolution: 0001;
    Instrument accuracy: 0.2% FS ± 1 bit;
    Sampling speed: 50 times / S;

    Common keywords:
    Intelligent digital pressure thermometer pressure temperature integrated control meter
    Pressure and temperature controller pressure and temperature digital display instrument
    Product description of strain type pressure transmitter:
    Model: PY602-602H-602S

    It integrates a number of international advanced electronic technology, single chip computer technology, electric erasure technology and anti-interference technology;
    It has the advantages of high measurement and control precision and strong anti-interference performance;
    The pressure and temperature are collected and controlled at the same time;
    Double four high brightness green and red LED, display resolution: 0001;
    Instrument accuracy: 0.2% FS ± 1 bit;
    Sampling speed: 50 times / S;

    Common keywords:
    Intelligent digital pressure thermometer pressure temperature integrated control meter
    Pressure and temperature controller pressure and temperature digital display instrument

    1、It integrates a number of international advanced electronic technology, single chip computer technology, electric erasure technology and anti-interference

    technology;
    2. It has the advantages of high measurement and control precision and strong anti-interference performance;
    3. Double four high brightness green and red LED, display resolution: 0001;
    4. Instrument accuracy: 0.2% FS ± 1 bit;
    5. Pressure input signal 2.0 / 3.3 MV / V, 4-20mA, 0-10vdc, RS485, etc;
    Temperature input signal: J, K, e, PT100 type sensor

    6. Sampling speed: 50 times / S;
    7. The whole machine is 96 × ninety-six × 100 (default);
    8. The whole machine is small in size, light in weight, low in power consumption, complete in function, reliable in operation, convenient and flexible in use;
    9. Equipped with our PT500 / PT100 series pressure transmitter / sensor, as a high-precision pressure measurement and control;
    10. It can set the upper and lower limit alarm, with LED alarm indication, relay contact output control external actuator;
    11. High precision voltage output module, current output module and relay output control module are optional;
    12. Rs485-rtu communication module is optional;
    13. Using the humanized operation method, the operation is simple and easy to learn;
    14. It can be widely used in hydraulic, petroleum, plastic, rubber, printing and dyeing, textile and other industries;


    Application fields:
    • Steam supply system

    • Oil pressure system

    • petrochemical industry

    • Petroleum Pipeline

    Specification parameter

    Display: double layer four digit high brightness green and red LED
    Display resolution: 0001
    Display range: - 999-9999 MPa (variable decimal point)
    Instrument accuracy: 0.2% FS ± 1 bit
    Indicator display: accuracy indicator, out output indicator, al1, al2 alarm indicator

    Pressure input signal:
    1 ~ 4MV / V four wire bridge
    4 ~ 20mA two wire system current
    Voltage type: 0 ~ 5VDC, 0 ~ 10VDC three wire system
    Rs485-rtu digital communication
    Temperature input signal: J, K, e, Pt100

    Supply voltage:
    220 VAC (85 ~ 265 VAC)/50 Hz~60 Hz
    24 VDC±5%

    Sampling speed: 50times/S
    Output control: voltage or current output that is linear with full scale signal
    Main alarm output: upper limit alarm has relay output (220V 1a), upper limit alarm indicator (out) is on, and can be equipped with peak value reservation (indicated

    when ordering)
    Auxiliary output: the auxiliary output can meet different output requirements through different function modules and instrument settings. See (V) module function

    description section for details. Optional auxiliary output (when ordering)
    Alarm range: - 999 ~ 9999 MPa (variable decimal point)
    Efficiency indication
    (equipped with melt sensor): display 80% of the full scale value of the sensor (the sensor should be unloaded), and the CAE is on
    Operating temperature and humidity: 0 ~ 55 ℃, ≤ 80% RH
    Dimensions: 96×96×100mm/96×48×100mm/48×48×100mm
    Opening size: 92×92mm /92×45mm /45×92mm
    Self weight: 400g/200g/200g



    Ordering considerations

    Precautions for PY602-602H-602S product ordering

    1. Instrument power supply voltage selection:
    220 VAC AC voltage
    24 VDC DC voltage

    2. Type of instrument input signal (matching with user transmitter / sensor output)
    Type of 4-20mA two-wire pressure / liquid level / temperature transmitter
    0-5vdc three wire pressure / liquid level / temperature transmitter
    0-10vdc three wire pressure / liquid level / temperature transmitter
    2.0 / 3.3mV pressure sensor / load cell
    Rs485-rtu digital communication signal transmitter
    Type selection of temperature sensor: J, K, e, Pt100

    3. Instrument output type (matching with user acquisition and control system)
    Two way relay output (default output type)
    Two relay outputs + one relay output
    Two relay outputs + one analog 4-20mA output
    Two relay outputs + one analog 0-10vdc output
    Two relay outputs + one digital RS485 output

    4. Users should understand the installation environment and installation mode of the product
    Indoor or outdoor installation (power box protection required);
    Ambient temperature;
    Vibration range of equipment;
    Whether the installation space meets the product dimensions;
    Precautions for use

    The type and scope of instrument power supply shall be provided according to the requirements of instrument;
    Instrument 16 foot grounding;
    Power supply and signal wire shall be correctly wired according to the requirements of product specification ordered;
    The output power of the relay at the output end of the instrument shall not exceed 220v/1a or 24v/1a;
    Pay attention to the protection instrument access and outgoing cable. When the span of field use is too large, it is recommended to use metal pipe to protect or

    overhead;
    The product is installed in a ventilated, dry and non corrosive environment. Protective devices are installed in the open air to avoid direct sunlight;
    Avoid direct access to user devices or appliances causing interference as far as possible;


    Common problem
    Proposal
    Name
    Tel
    QQ
    WeChat
    Mailbox
    Address
    Content
    Foshan puliang Electronic Co., Ltd

    Tel:0757-26619568 Fax: 0757-26619508

    24-hour online technical support:13790092618

    Cloud platform:www.puliangiot.com

    Address:501, block 8, phase 5, Rongli tianfulai industrial city, Ronggui town, Shunde District, Foshan City

    Copyright©Foshan puliang Electronic Co., Ltd