Product description of strain type pressure transmitter:
Chip:
Flat film / diaphragm pressure sensing and anti blocking structure design, suitable for melt / fluid medium;
Adopt imported pressure sensitive chip; select the chip technology;
High impedance, high precision and high stability;
Diaphragm structure: thick film piezoresistive, thin film silicon chip, flange type large diaphragm;
More than 1 million service life;
Signal processing and output:
24 bit ADC sampling processing chip;
DSP digital signal conditioning algorithm;
Multipoint line temperature calibration;
Voltage and current overload protection;
Four position pressure indicator;
Display range: - 1999-9999;
Sampling rate: 10 times / S;
Standard 4-20mA two-wire current loop output signal;
Structure:
Thick film structure: deep argon arc welding, connecting elastic material and process joint, high strength, impact resistance, fatigue resistance;
Thin film structure: laser welding, connecting elastic materials and process joints, silicon oil medium transfer pressure, fast response, fatigue resistance, small range;
Din43650 Hersman standard electrical connector;
Supporting standard four core shielded cable;
The overall structure is small and the process connection mode is diversified (m20x1.5, G1 / 2, ZG1 / 2, 1 / 2NPT (thread diameter ≥ 17mm) DN50, etc.);
Process connection material: 304 or 316;
Application:
Melt / fluid / viscous medium pressure measurement and control;
Equipment pressure measurement in industry / power / oil / automation and other fields
Specification parameter
Technical parameters
Measuring medium: melt, fluid, liquid and gas containing impurities (such as paint, toothpaste, pigment, etc.)
Pressure form: gauge pressure, absolute pressure
Range: 0 ~ 0.6, 1, 2, 5, 10, 15, 20, 25, 30, 40, 50, 60, 100 (MPA);
0~10、20、30、50、100、150、200、300、400、500、600(KPa);
-100KPa~10KPa~40MPa;
±10KPa~±100KPa;
Comprehensive accuracy: ± 0.25% FS; ± 0.5% FS; ± 1% FS
Non linear: ≤ 0.25% FS
Repeatability: ≤ 0.1% FS
Output signal: 4-20mA two-wire system;
Four digit display, display range: - 1999 - 9999
Sampling rate of pressure gauge: 10 times / S
Power supply voltage: 24VDC (9-30vdc)
Service life: ≥ 1 million times
Insulation impedance: ≥ 1000m Ω / 100VDC
Load impedance: current output: ≤ 800 Ω; voltage output: ≥ 50K Ω
Medium temperature: - 20-80 ℃
Ambient temperature: - 20 ~ 70 ℃
Compensation temperature: 0 ~ 70 ℃
Response time: ≤ 5ms
Overload pressure: 150% FS
Failure pressure: 3 times of range (range less than 40MPa); 2 times of range (range greater than 41mpa)
Electrical connection: din43650 Hersman standard electrical connector
Protection grade: IP65
Connecting cable: four core shielded cable, standard length: 3M
Connection material: 304/316L
Process connection: m20x1.5, G1 / 2, ZG1 / 2, 1 / 2NPT, DN50 Specifications can be made by users
三、結構尺寸
四、電氣連接
五、安裝方式
Ordering considerations
1. Product range selection:
In order to achieve the best effect of product accuracy, life, stability and other functions, the range selection of the product is calculated by referring to the following formula:
Range = x (1.2-1.5) times of the maximum system pressure;
The actual measuring pressure range of the product should be 15% - 80% of the range;
2. Product power supply and output:
The selection of power supply range is determined according to the output specifications of the product:
Conventional 4-20mA, DC 12-30vdc power supply;
Display header, four places, one decimal place;
3. The user should understand the measurement medium characteristics of the product:
Medium specification, medium temperature, medium purity (whether containing impurities or particles, etc.);
4. Users should understand the installation environment and installation method of the product:
Indoor or outdoor installation;
Ambient temperature;
Required sealing level;
Vibration range of equipment;
Installation method: thread, flange, special structure;
Whether the installation space meets the overall dimension of the product;